Touchscreen Colourful Programmable Modbus Thermostat for On&Off Control of GasBoiler Dry Contact (with Modbus RS485 Function)

Quick Details

Description

Place of Origin: Shanghai, China (Mainland)

Brand Name: SML

Model Number: SML-1000GD (Bolier Dry Contact)

Type: HVAC Systems

Power Supply: 24VAC/110VAC/220VAC

Current Load: 3A

Application: Boiler Control

Housing Color: White/Black

Delivery Detail: Shipped in 1 day after payment

Frame Color: Silver/Gold

Backlight: Blue

Installation Box: European 60mm round box

Packaging

UNIT WEIGHT: 0.25KG/PC;

GROSS WEIGHT: 0.265KG;

PAPER BOX PACKING;

BOX DIMENSION: 48*48*35CM

Delivery Detail: Shipped in 1 day after payment

Feature

C – Convenient operation creates convenient life.

O – Options of white or colorful words on the black screen.

M – Manage your home even when you are in any place around the world at any time.

F – Fashion design blends in with any need

O – Zero service fee.

R – Remote controlled by mobile APP (ANDROID OR IOS system).

T-Touch Screen display with backlight is easy to read-even in the dark.

A – Accuracy of 0.5 keeps your comfortable temperature within the level you set.

B – Blue button lights always remind you the world truely exist.

L – Lovely price helps you save not only energy.

E – Easy UI interface could be used even by child.

Brief Introduction

SML-1000 series Modern Touch Screen Room Thermostats are designed to on/off control the valve of the water piping via comparison of the room temperature and setting temp. as reaching the aim of comfort and saving energy by your mobile phone. No matter you stay at home or abroad, you can control your room temp. easily.

Techinical Data

Sensor NTC 10K Current Load 3A
Accuracy 0.5 Shell Material PC+ABS (Fireproof)
Temp. Range 5 -35 Dimension 86x86x13.3mm
Power Consumption <1.5W Ambient Temp.

0 ~ 45 5 ~ 95%RH

(Non condensing)

Power Supply 95~240VAC, 50 ~60Hz Storage Temp -5~ 55
Certificate CE, RoHS Warranty 18 Months
Programmable 5+2 four periods Delivery Time

Sample: In 1 days after payment

Bulk: In 15 days after payment

Dimension

Wiring Diagram

Wate/Gas Boiler

Installation


Operation

Modbus Protocol

This protocol takes standard MODBUS as a reference, mainly use for communication between thermostat and upper computer. This protocol doesn’t describe the MODBUS. As to standard MODBUS, please refer to the relevant standard documents.

1. Basic description

No

Parameter

Protocol provision

1

Operating mode

RS-485,master-slave;thermostat is the slave machine

2

Physical interface

A(+),B(-) two-wire system

3

Baud rate

9600 bps for standard

4

Byte format

9 format (8 data bits +1 stop bit)

5

Modbus

RTU

6

Transmission mode

RTU format (Please refer to standard MODBUS)

7

Thermostat address

1-255;

8

Command code

03,06(03—read thermostat, 06—set thermostat)

9

CRC check code

CRC-16 (Please refer to standard MODBUS)

10

CRC verification mode

CRC-16 (Please refer to standard MODBUS)

2. Read the thermostat frame format

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Thermostat address (default is 0X01)

03

Set register start address high byte

Set register start address low byte

Set register value high address

Set register value low address

CRC high

CRC low

Command

Byte

Description

Register address

03

High Byte

00

40001

Low Byte

Setting Power On/off: 0x5A–means closed, 0xA5–means open

High Byte

00

40002

Low Byte

High Temperature Protection Range: Data is HEX code

High Byte

00

40003

Low Byte

Temperature for external sensor: Data is HEX code

High Byte

00

40004

Low Byte

Temperature for internal sensor: Data is HEX code

High Byte

00

40005

Low Byte

Setting Temperature: Data is HEX code

3. Set the thermostat frame format

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Thermostat address (default is 0X01)

06

Set register start address high byte

Set register start address low byte

Set value high address

Set value low address

CRC high

CRC low

Command

Byte

Description

Register address

06

High Byte

00

40001

Low Byte

Setting Power On/off: 0x5A–means close, 0xA5–means open

High Byte

00

40002

Low Byte

High Temperature Protection Range: Data is HEX code

High Byte

00

40003

Low Byte

Temperature for external sensor: Data is HEX code

High Byte

00

40004

Low Byte

Temperature for internal sensor: Data is HEX code

High Byte

00

40005

Low Byte

Setting Temperature: Data is HEX code

High Byte

00

40006

Low Byte

Setting Minute

High Byte

00

40007

Low Byte

Setting Hour

High Byte

00

40008

Low Byte

Setting Mode: 00 means Weekly program 01 means Manual

Remark:

1. When thermostat sends collected temperature data to upper computer, the value of collected temperature should be multiplied by 2 and sent completely by the format of HEX because the accuracy is 0.5℃.

For example: When the collected temperature is 25.5℃, the value sent by thermostat to the upper computer will be 33H (the demical is 51 );

Similarly, When upper computer sends set temperature data to thermostat, the value of set temperature should be multiplied by 2 and sent completely by the format of HEX because the accuracy is 0.5℃.

For example: When the set temperature is 25.5℃, the value sent by upper computer to the thermostat should be 33H (the demical is 51).

E.G.: Read Temper= 25.5°C

The send(or receive) value is 25.5*2=51

The data in HEX =33H

2. How to change thermostat IP address?

During power off, press button M and button Clock for 5 seconds at the same time into high senior options.

Press M to item 2.

Then press up and down to change the relative value. The default is 0x01.

All data will be saved only after a restart.